Femtosecond laser technology arrived on the refractive surgery scene several years ago, and surgeons responded positively to what they viewed as a quantum leap in flap-making technology. Since this time, femtosecond use has exploded exponentially, with promises to revolutionize how we conduct laser surgery.
Many practices no longer use a bladed microkeratome and, as occurred with intra- and extracapsular cataract surgery after the introduction of phacoemulsification, there will soon be generations of laser eye surgeons who will not know how to use a mechanical microkeratome. As is the case with so many new technologies, the transition can be fraught with problems and a learning curve—things that many surgeons do not consider amid all of the advantages that this technology offers. This article provides brief but balanced view of the difficulties associated with making the change from mechanical microkeratome to femtosecond laser. I also review some of the complications associated with femtosecond flaps.
COST
One of the biggest obstacles to entry into the femtosecond
world is cost. Many European ophthalmologists
partake in refractive surgery on a part-time basis,
combining it with work in other subspecialities. For
these surgeons, the cost of acquiring femtosecond technology
can be prohibitive, unless they group together
with other surgeons to share a machine or use a mobile
fee-per-procedure platform. The tendency for larger
commercial laser practices to offer femtosecond flaps
places additional pressure on the solo refractive surgeon
to embrace the technology.
Femtosecond platforms currently on the market are the Femto LDV (Ziemer Group, Port, Switzerland), IntraLase FS60/iFS femtosecond laser (Abbott Medical Optics Inc., Santa Ana, California), Technolas 520F (Technolas Perfect Vision GmbH, Munich, Germany), and the VisuMax (Carl Zeiss Meditec, Jena, Germany). Other models are under development, including the WaveLight FS-200 (Erlangen, Germany), which may be released as early as September.
INTRAOPERATIVE COMPLICATIONS
Femtosecond flap complications can be divided
broadly into two categories, intraoperative and postoperative
events. Intraoperative complications
include opaque bubble layer (OBL), vertical gas breakthrough,
thin flaps, horizontal gas breakthrough, suction
break, gas bubbles in the anterior chamber, and
decentered flaps.
OBL. This complication is a collection of gas bubbles in the intralamellar spaces above and below the resection plane. Early or hard OBL (Figure 1A) spreads ahead of the raster pattern, and late or soft OBL (Figure 1B) appears as opaque patches in areas where the raster pattern has already passed through.
Early OBL can interfere with the effectiveness of additional laser pulses and make flap lifting more difficult. Excessive OBL can impede some excimer laser tracking systems and can obstruct or distort ultrasound measurements taken during intraoperative pachymetry. The surgeon can avoid OBL by adjusting the pocket depth, pocket width, pocket spot/line separation, and hinge angle, all in an effort to optimize gas evacuation. Some surgeons have found that lighter applanation also reduces OBL. In some corneas, starting the pattern near the limbus can allow gas to collect circumferentially in the perilimbal area, reducing OBL. Lastly, modifying the raster energy and/or spot/line separation can potentially minimize OBL.
Vertical gas breakthrough. Although uncommon, vertical gas breakthrough breakthrough (incidence, 0.1%; Figure 2) can occur if the laser flap is programmed too thin—generally 100 μm or less—or if there is a focal break or scar in Bowman's membrane.
Thin flaps. This complication (Figure 3) is similar in cause and effect to vertical gas breakthrough. To verify a safe flap thickness, the surgeon should use the bubble pachymetry technique prior to lifting.
Horizontal gas breakthrough (HGB). Occurring when the pocket is overly efficient and the gas is vented in quick bursts, HGB can potentially leave an irregular pattern on the stromal bed. The likelihood of HGB can be decreased with good docking techniques and appropriate raster and pocket settings.
Suction break. Management occurs in one of two ways: Either the procedure is repeated immediately using the same cone or the procedure is abandoned and repeated after a variable period of days to weeks. In these situations, there is a profound difference and advantage over an incomplete microkeratome flap, in which immediate abandonment is mandatory and the subsequent treatment is inevitably a surface procedure after a much longer delay. Some would say that this is the single-most important reason for converting to femtosecond flaps. Suction breaks can be avoided in several ways:
•Assure proper centration and suction before
docking;
•Avoid all horizontal and vertical
movements of the gantry as
soon as the cone is docked;
•Avoid major hand movements
when holding the suction ring
assembly;
•Continually monitor the
applanated area after the downward
movement is completed;
and
•Reassure the patient while the
laser is firing to keep him calm
and relaxed.
Gas bubbles in the anterior
chamber.
The presence of gas
bubbles in the anterior chamber
(Figure 4) is a relatively rare
complication of femtosecond
flaps. When it occurs, gas bubbles
diffuse into the anterior
chamber during flap creation.
Some may not regard this as a
true complication; however, the
bubbles may disrupt the
excimer laser's tracking system.
Treatment is delayed by several minutes to several
hours while waiting for the bubbles to fully dissipate.
Decentered flaps. The following techniques help
avoid decentered flaps:
•Prescreen patients to identify larger shifts in their
angle kappa;
•Mark the visual axis as a target for the suction ring;
•Eliminate all horizontal and vertical movements of
the gantry as the cone is docked; and
•When applanation is complete, verify that the suction
ring assembly is level.
Do not accept an effective loss in flap diameter of
greater than 0.5 mm, as this may compromise the effectiveness
of your laser treatment.
POSTOPERATIVE EVENTS
Inflammation or diffuse lamellar keratitis (DLK), photophobia
and transient light sensitivity syndrome (TLSS), striae,
and epithelial ingrowth have all been associated with
femtosecond laser flap creation.
Inflammation or DLK. Associated with LASIK, DLK (Figure 5) is characterized by appearance of a noninfectious inflammatory reaction in the interface, usually noticeable 1 to 5 days after LASIK. The etiology and pathogenesis is multifaceted. The incidence is lower with newer, lower-energy femtosecond lasers such as the 60-kHz IntraLase. Management of DLK includes intense steroid drop therapy or flap washout, depending on the severity or grading.
Photophobia and TLSS. These are rare phenomena usually appearing 2 to 6 weeks postoperatively. Patients can present with moderate to extreme light sensitivity, a good UCVA, and no slit-lamp findings. As it may be related to energy and keratocyte activation (Figure 6), TLSS too has nearly disappeared with the production of lower-energy femtosecond lasers.
Striae and epithelial ingrowth. Although they can occur with microkeratome and femtosecond flaps alike, striae and epithelial ingrowth (Figure 7) are less likely to occur with the femtosecond laser due to flap biomechanics. The beveled flap-edge angle provides greater flap stability due to the so-called manhole cover effect. Management follows the same protocol as for microkeratome- related striae and epithelial ingrowth.
CONCLUSION
Most refractive surgeons, and even cataract surgeons,
are aware of the benefits associated with the use of the
femtosecond laser; however, the drawbacks are not
commonly mentioned. When weighing the pros and
cons of transitioning to femtosecond laser technology
for flap creation, such drawbacks as the cost and complications
should not be overlooked.
Wayne Crewe-Brown, MD, is a Consultant Ophthalmic Surgeon at Kirkwood Fyfe Clinic, UKSH NHS Treatment Centre, and the Director of Visiocare Consultants Ltd., both in the United Kingdon, and a Consultant Ophthalmic Surgeon at Optilase Laser Eye Clinics, in Ireland. Dr. Crewe-Brown states that he is a paid physician trainer for Abbott Medical Optics Inc., but otherwise has no financial interest in the products or companies mentioned. He may be reached at e-mail: waynecrewebrown@aol.com.