Refractive Surgery | Feb 2011

Premium Corneal Ablations With Zyoptix

This system provides both wavefront-guided and wavefront-optimized corrections.

Conventional excimer laser corneal ablations induce changes in corneal shape and thus corneal asphericity, leading to an increase in higher-order aberrations (HOAs) and degradation of visual performance measures including night vision and contrast sensitivity. 1-4 The increase in HOAs, particularly fourth-order spherical aberration, is related to several factors that include the amount and type of correction, the ablation profile, the biomechanics of the corneal response, and corneal wound healing.5-9 Premium, or customized, excimer laser corneal ablations typically avoid some of the visual disturbances associated with refractive surgery.

For customized surgery, most excimer laser platforms employ wavefront-guided treatments; another available option is wavefront-optimized treatment. The Zyoptix platform, which combines the Technolas 217 Z100 excimer laser (Technolas Perfect Vision GmbH, Munich, Germany) with the Zyoptix diagnostic workstation (Technolas Perfect Vision GmbH) for wavefront aberration examination and Zylink treatment software, now has the capability to perform either type of custom ablation profile.

Wavefront-guided surgery is a keratorefractive technique that corrects both preexisting lower-order aberrations (LOAs; ie, spherocylindrical error), and corneal HOAs. Conversely, wavefront-optimized laser profiles preserve preexisting ocular aberrations and optimize the asphericity of the cornea. These procedures consider corneal asphericity (Q) in the ablation algorithm. Both wavefront-guided and wavefront-optimized treatments improve visual performance compared with conventional ablation.10-15

EFFICACY OF THE ZYOPTIX PLATFORM
The Zyoptix platform has been used internationally since 2001, and many surgeons have confirmed the efficacy of its wavefront-guided ablations during PRK and LASIK.16-21 The Tecnolas 217 Z100 is a flying-spot excimer laser that uses truncated Gaussian spots of 2- and 1-mm diameter for the correction of LOAs and HOAs, respectively, in the Zyoptix procedure. The Zywave aberrometer creates a personalized ablation profile that corrects preexisting HOAs and LOAs.

Zyoptix wavefront-guided ablations demonstrated less increase in postoperative HOAs compared with standard ablation in several studies.16-18 In our own study, PRK with the Zyoptix wavefront-guided platform was related to less increase of root mean square (RMS) of total HOAs. We suspect this is related to the tissue-saving effect of the wavefront- guided ablation software. Moreover, we observed a reduction of preoperative third-order coma aberrations, predominantly in the physiologic corneal wavefront error, and particularly for higher preoperative values, related to the ablation profile calculated from wavefront measurement.19

More recently, additional algorithms have become available for the Zyoptix system. These allow aspheric ablation patterns as well as combined aspheric and wavefront patterns. The aspheric algorithm has demonstrated greater efficacy in reducing induced spherical aberration and preserving corneal asphericity compared with conventional and wavefront-guided ablations.20,21 The combined aspheric and wavefront algorithm showed good correction of LOAs and HOAs with no induction of spherical aberration and with improvement in quality of vision.22

CONCLUSION
The Zyoptix system performs both wavefront-guided and wavefront-optimized treatments, and clinical results confirm the efficacy of both techniques. In my experience, the wavefront-guided ablation algorithm is particularly useful in eyes with higher preoperative RMS values, and the aspheric ablation is essential to maintain corneal asphericity and provide optimal vision.

Randomized studies comparing algorithms for the Zyoptix and other laser systems would be useful to enable us to understand the individual contribution of wavefront-guided and wavefront-optimized laser ablations. It would also help to identify patients suitable for different treatment options and those who would benefit from a combined wavefront-optimized treatment.

Leonardo Mastropasqua, MD, is the Director of the Ophthalmology Clinic, Regional Center of Excellence in Ophthalmology, University G. D’Annunzio of Chieti and Pescara, Italy. Dr. Mastropasqua states that he has no financial interest in the products or companies mentioned. He may be reached at e-mail: l.mastropasqua@unich.it.

Lisa Toto, MD, is a researcher at the Ophthalmology Clinic, Regional Center of Excellence in Ophthalmology, University G. D’Annunzio of Chieti and Pescara, Italy. Dr. Toto states that she has no financial interest in the products or companies mentioned. She may be reached at e-mail: l.toto@unich.it.

  1. Martinez CE,Applegate RA,Klyce SD,et al.Effect of pupillary dilation on corneal optical aberrations after photorefractive keratectomy. Arch Ophthalmol. 1998;116:1053-1062.
  2. Oshika T,Klyce SD,Applegate RA,et al.Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis.Am J Ophthalmol. 1999;127:1-7.
  3. Seiler T,Kaemmerer M,Mierdel P,Krinke H-E.Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism.Arch Opthalmol. 2000;118:17-21.
  4. Oliver KM,O’Brart DPS,Stephenson CG,et al.Anterior corneal optical aberrations induced by photorefractive keratectomy for hyperopia.J Refract Surg.2001;17:406-413.
  5. Roberts C.The cornea is not a piece of plastic.J Refract Surg.2000;16:407-413.
  6. Wilson SE,Moham RR,Hong JH,et al.The wound healing response after laser in situ keratomileusis and photorefractive keratectomy. Arch Ophthalmol.2001;119:889-896.
  7. Schwiegerling J,Snyder RW.Corneal ablation patterns to correct for spherical aberration in photorefractive keratectomy.J Cataract Refract Surg.2000;26:214-221.
  8. Moreno-Barriuso E,Merayo-Lloves J,Marcos S,et al.Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing.Invest Ophthalmol Vis Sci.2001;42:1396-1403.
  9. Mrochen M,Kaemmerer M,Mierdel P,Seiler T.Increased higher-order optical aberrations after laser refractive surgery:a problem of subclinical decentration.J Cat Refract Surg.2001;27:362-369.
  10. Mrochen M,Kaemmerer M,Seiler T.Clinical result of wavefront-guided laser in situ keratomileusis 3 months after surgery.J Cat Refract Surg. 2001;27:201-207.
  11. Kanjani N,Jacob S,Agarwal A,et al.Wavefront-guided laser in situ keratomileusis with the Bausch & Lomb Zyoptix system. J Cataract Refract Surg.2004;20:35-39.
  12. Mastropasqua L,Nubile M,Ciancaglini M,et al.Wavefront-guided excimer laser photorefractive keratectomy in myopic patients:a prospective randomised study.J Refract Surg.2004;20:422-431.
  13. Nuijts RMMA,Nabar VA,Hament WJ,Eggink FAGJ.Wavefront-guided versus standard laser in situ keratomileusis to correct low to moderate myopia.J Cat Refract Surg.2002;28:1907-1913.
  14. Panagopoulou SI,Pallikaris IG.Wavefront customized ablations with the WASCA Asclepion Workstation.J Refract Surg. 2001;17:S608-612.
  15. Myrowitz EH,Chuck RS.A comparison of wavefront-optimized and wavefront-guided ablations.Curr Opin Ophthalmol. 2009;20:247-250.
  16. Kim TI,Yang SJ,Tchah H.Bilateral comparison of wavefront-guided versus conventional laser in situ keratomileusis with Bausch and Lomb Zyoptix.J Refract Surg.2004;18:S620-623.
  17. Kohnen T,Buhren J,Kuhne C,Mirshahi A.Wavefront-guided LASIK with the Zyoptix 3.1 system for the correction of myopia and compound myopic astigmatism with 1-year follow-up.Ophthalmol.2004;111:2175-2185.
  18. Cosar CB,Saltuk G,Sener AB.Wavefront-guided laser in situ keratomileusis with the Bausch and Lomb Zyoptix system.J Refract Surg.2004;20(1):35-39.
  19. Mastropasqua L,Toto L,Zuppardi E,et al.Zyoptix wavefront-guided versus standard photorefractive keratectomy (PRK) in low and moderate myopia:randomized controlled six-month study.Eur J Ophthalmol. 2006;16:219-228.
  20. Ang RE,Chan WK,Wee TL,et al. Efficacy of an aspheric treatment algorithm in decreasing induced spherical aberration after laser in situ keratomileusis.J Cataract Refract Surg.2009;35:1348-1357.
  21. Taneri S,Stottmeister S.Aspheric ablation for the correction of myopia:clinical results after LASIK with a Bausch & Lomb 217 Z 100 excimer laser.Klin Monbl Augenheilkd.2009;226:101-109.
  22. Duch F.Results of the new Personalized Treatment Advanced algorithm for excimer laser surgery using the Zyoptix Technolas Perfect Vision platform.Paper presented at:the XXVIII Congress of the ESCRS;September 4-8, 2010;Paris.

Feb 2011